Zero static.Zero particles.Zero guesswork.
Ace Star supplies, installs and audits the cleanroom and ESD-control systems behind Southeast Asia's semiconductor and electronics lines, from the factory door to the last ionizer on the bench.
Five stations between dirt and a die.
Static and particles enter a clean factory in predictable places. We supply and install the control at each one, so nothing reaches the product.






Stop it at the door.
Shoes and wheels carry about 80% of indoor micro-dust. ProfilGate grates, rated to 30 tonnes, brush forklift tyres and trolley castors clean. SWC machines scrub shoe soles the moment someone steps on, and washable SlimDust mats catch what's left in three footfalls.

Dress the operator, not just the room.
People are a cleanroom's biggest contamination source. Jumpsuits, smocks and hoods come standard or tailor-made. Footwear comes in dissipative (10⁶–10⁹ Ω) and conductive grades. Gloves, masks and disposables complete the gowning list.

Ground every step.
Ace Star represents HexStat and supplies ESDWork conductive and dissipative tiles, laid over a copper-tape grid of 6 to 10 m. Where forklifts run, the floor is ESD epoxy compliant with S20.20. We also repair and maintain HexStat, ESDWork, Forbo, Polyflor and Gerflor floors.

Neutralise what grounding can't.
Insulators don't drain to ground, so balanced ions do the work. Shishido ionizers hold offset voltage under 5 V. They sit on Vessel RoHS2 mats beside wrist straps, ESD tools and Trek voltmeters that prove the bench is under control.

Ship it shielded.
Static-shielding and moisture-barrier bags, conductive foams, vacuum-formed trays, IC tubes, carrier tape, magazine racks and conductive bins keep parts protected from the line to the loading bay.
205 products. One enquiry list.
Every product from the old website, rebuilt as a searchable catalogue. Pick items from any family and send one quotation request to the nearest office.
Clean Factory Entry
Stop dirt at the door — wheel, sole and trolley decontamination.



ESD Flooring
HexStat & ESDWork tiles, ESD epoxy, finishes. Supplied, installed, repaired.
Ionizers & Test Equipment
Shishido ionizers, field meters and ESD testers that prove control.




Cleanroom Consumables
Garments, gloves, footwear, wipes and swabs for controlled environments.


ESD Packaging
Shielding bags, foams, trays, tubes and tapes that protect in transit.


Material Handling
Racks, bins and curtains that keep parts grounded between steps.


Workstation & Grounding
Mats, wrist straps, grounding cords, tapes and tools for the EPA bench.


Catalogued SKUs, searchable by code, name or spec. Add them to one enquiry list and send it to the nearest office.
Open the catalogueIon balance, measured in single volts.
Grounding can't drain an insulator, but balanced ions can. Pick a Shishido WINSTAT model to see its footprint, ion technology and rated offset voltage: how close to zero it holds your product.

No pass, no entry. Every step logged.
Ace Star designs and builds its own ESD test-and-access system, hardware and software. The iDS-600 tests each shoe and the wrist strap at a turnstile, flap gate or door before it lets anyone onto the production floor.
- Tests the left shoe, right shoe and wrist strap separately, or all at once, configured in software.
- LCD readout in ohms, with LED and buzzer verdicts operators can't miss.
- I/O for card readers, access control and data loggers. Turnstile, flap gate, magnetic door lock or infrared sensor.
- Upgradeable with face recognition and thermal body-temperature scanning.
- Data-logging software written by Ace Star's own engineers logs every entry and flags anyone who skips the test.



Simulation for illustration. Real pass band is 100 kΩ to 120 MΩ, set per customer.
Prove control. Then keep it.
Supplying the gear is half the job. Our engineers test, audit and train, so your ESD programme holds up when your customer's auditor walks in.

On-site ESD test & audit
Led by an iNARTE-certified ESD engineer. TR53 compliance verification plus seven ANSI/ESD test methods run on your own floor.

Low-humidity lab testing
Qualify garments, work surfaces, floors and footwear at 12% RH ±3% and 23 °C ±3 °C after 72 hours of preconditioning.

S20.20 consultation
Planning ANSI/ESD S20.20 certification? We prepare your programme and point you to the nearest accredited certification body.

Seminars & training
On-site ESD training, plus seminars with Shishido of Japan in Penang (2018 and 2019), covering ionizers, measurement and cleanroom dust control.
Certified to check, not just to sell.
Tap a certificate to inspect it.

ISO 9001:2015
Certificate 050826016014 (ARS Assessment). Recertified 5 Aug 2026; first surveillance due 10 Jul 2027. Scope: supply of cleanroom and ESD products, ESD control, and building, facility & equipment maintenance.

iNARTE ESD Control Engineer
Ace Star's test and audit service is led by an iNARTE-certified Electrostatic Discharge Control Engineer, Low Choon Huat.

ESD TR53 compliance verification
Field engineers are certified to TR53 compliance verification of ESD control items: floors, mats, garments, ionizers and grounding.
Six offices. One standard.
Penang, the Klang Valley and Johor in Malaysia, plus Singapore, Batam and Pathum Thani through Aceplas and Pro-Pack. Stock and engineers stay close to the line.
Know your floor before you buy it.
Straight answers from years of laying, testing and repairing ESD floors.
Conductive or dissipative tile?
Conductive tile runs 2.5×10⁴ to 10⁶ Ω, dissipative 10⁶ to 10⁹ Ω. Both meet S20.20, and both cost the same.
Read the answer ToolThe resistance ruler
Type in a meter reading and see where it sits against tile classes, the S20.20 floor limit and the iDS-600 pass band.
Try it MaintenanceDaily, monthly, yearly
The tile care schedule that keeps resistance in spec. Never use normal wax.
See the schedule
Start an enquiry
Tell us what's on your line.
Send a parts list, a floor plan or just a problem. We'll come back with the right products, a quotation and, if it helps, a site visit.